Boiler denitrification treatment

The flue gas denitration technology mainly includes dry method (selective catalytic reduction flue gas denitration, selective non-catalytic reduction denitration) and wet method. Compared with wet flue gas denitration technology, the main advantages of dry flue gas denitration technology are: low basic investment, simple equipment and process, high efficiency in removing NOX, no waste water and waste treatment, not easy to cause two Secondary pollution.

Key words:

treatment the and to is of nox absorption flue gas

Service line:

Detailed

Technology Introduction

The flue gas denitration technology mainly includes dry method (selective catalytic reduction flue gas denitration, selective non-catalytic reduction denitration) and wet method. Compared with wet flue gas denitration technology, the main advantages of dry flue gas denitration technology are: low basic investment, simple equipment and process, high efficiency in removing NOX, no waste water and waste treatment, not easy to cause two Secondary pollution.

Technical advantages

Method:

 Flue gas denitrification refers to the reduction of NOX produced to N2, thereby removing NOX from flue gas. According to the treatment process, it can be divided into wet denitration and dry denitration. Some researchers at home and abroad have also developed methods for treating NOX waste gas with microorganisms.

Since 90% or more of NOx in the flue gas discharged from the combustion system is NO, and NO is hardly soluble in water, the wet treatment of NOx cannot be performed by a simple washing method. The principle of flue gas denitration is to oxidize NO to NO2 with an oxidant, and the generated NO2 is absorbed by water or an alkaline solution to achieve denitration. The O3 oxidation absorption method oxidizes NO to NO2 with O3 and then absorbs it with water. The HNO3 liquid of the method needs to be concentrated, and O3 requires high voltage production, and the initial investment and operating cost are high. ClO2 redox method ClO2 oxidizes NO to NO2, and then reduces NO2 to N2 with an aqueous solution of Na2SO3. The method can be combined with a wet desulfurization technology using NaOH as a desulfurizing agent, and the desulfurization reaction product Na2SO3 can be used as a reducing agent for NO2. The dechlorination rate of the ClO2 method can reach 95%, and the sulfur can be simultaneously desulfurized, but the price of ClO2 and NaOH is higher, and the running cost is increased.

Wet flue gas denitration technology:

Wet flue gas denitrification is the principle of using liquid absorbent to dissolve NOX to purify coal-fired flue gas. The biggest obstacle is that NO is difficult to dissolve in water, and it is often required to first oxidize NO to NO2. For this reason, NO is generally first reacted with an oxidant O3, ClO2 or KMnO4 to form NO2, and then NO2 is absorbed by water or an alkaline solution to achieve flue gas denitration.

(1) Dilute nitric acid absorption method

Since the solubility of NO and NO2 in nitric acid is much greater than in water (for example, the solubility of NO in 12% nitric acid is 12 times greater than that in water), dilute nitric acid absorption is used to increase NOX removal rate. The technology is widely used. As the concentration of nitric acid increases, the absorption efficiency increases remarkably. However, considering the practical application and cost of the industry, the concentration of nitric acid used in actual operation is generally controlled within the range of 15% to 20%. The efficiency of NOx absorption by dilute nitric acid is related to the absorption temperature and pressure, and the low temperature and high pressure is beneficial to the absorption of NOX.

(2) Alkaline solution absorption method

The method adopts an alkaline solution such as NaOH, KOH, Na2CO3, NH3·H2O as an absorbent to chemically absorb NOX, wherein ammonia (NH3·H2O) has the highest absorption rate. In order to further improve the absorption efficiency of NOX, two-stage absorption of ammonia-alkali solution was developed: first, ammonia was completely gas-phased with NOx and water vapor to form ammonium nitrate white smoke; then unreacted NOX was further absorbed by an alkaline solution. Nitrate and nitrite are formed, and NH4NO3 and NH4NO2 will also be dissolved in the alkaline solution. After the absorption liquid is circulated a plurality of times and the alkali solution is exhausted, the solution containing the nitrate and the nitrite is concentrated and crystallized, and can be used as a fertilizer.

Related items

Ship engine exhaust gas treatment


Nitrogen oxide in the exhaust gas of marine generator set is a gas formed by the oxidation of nitrogen in the cylinder at high temperature, which is mainly composed of nitric oxide and nitrogen dioxide. Green Valley environmental protection has developed a set of "grvnes" SCR denitration system for the treatment of nitrogen oxides in the waste gas discharged by marine generators after years of painstaking research. After special design, the system can still realize high-efficiency operation under the condition of unstable exhaust temperature and gas quality; Important parts can withstand the common impurities in landfill gas and ensure the long-term stable operation of the system.

Diesel power generation waste gas treatment


Nitrogen oxides in the exhaust gas of diesel generator set are gases formed by the oxidation of nitrogen in the cylinder at high temperature, mainly composed of nitric oxide and nitrogen dioxide. Green Valley environmental protection aims at the treatment equipment of PM (particulate matter) and NOx (nitrogen oxide) in the exhaust gas of diesel generator set. Green Valley company has developed the integrated design of particle trap and SCR denitration system. The particle trap is used to treat the PM (particulate matter) in the waste gas to make it meet the environmental protection standard; SCR denitration system aims at NOx (nitrogen oxide) in waste gas to make it meet local environmental protection standards (specific standards are customized according to customer requirements).

Waste treatment and power generation exhaust treatment


Green Valley environmental protection has developed a set of "grvnes" SCR denitration system for nitrogen oxide treatment in landfill gas power generation after years of painstaking research. After special design, the system can still realize high-efficiency operation under the condition of unstable exhaust temperature and gas quality; Important parts can withstand the common impurities in landfill gas and ensure the long-term stable operation of the system.

Distributed energy exhaust treatment


Green Valley environmental protection has developed a set of "grvnes" SCR denitration system for the treatment of nitrogen oxides in distributed energy power generation after years of painstaking research. After special design, the system can still realize high-efficiency operation under the condition of unstable exhaust temperature and gas quality; Important parts can withstand the common impurities in landfill gas and ensure the long-term stable operation of the system.

Denitration treatment of power plant


Selective catalytic reduction (SCR) is used to control NOx in diesel engine exhaust. NH3 or urea (usually urea aqueous solution with mass ratio of 32.5%) is used as reducing substance. Under the condition that O2 concentration is more than two orders of magnitude higher than NOx concentration, under the action of certain temperature and catalyst, NH3 is used to reduce NOx to N2 and H2O. Because NH3 is highly selective, NOx is preferentially reduced, It does not react with O2 first, so it is called "selective catalytic reduction". For excess NH3, a certain proportion of ammonia escape catalyst (ASC) is coated at the end of SCR carrier to ensure that NH3 reacts with O2 to generate N2 and H2O and avoid secondary pollution caused by NH3 leakage. The exhaust temperature after diesel engine or gas engine turbine is generally in the range of 300 ℃ to 500 ℃, which meets the temperature conditions required for medium temperature catalytic reaction. If the temperature after vortex is higher than 500 ℃, high-temperature catalyst shall be considered, and the system cost will increase in a certain proportion.

Waste gas treatment of standby power supply


Green Valley environmental protection has developed a set of "grvnes" SCR denitration system for the treatment of nitrogen oxides in natural gas power generation after years of painstaking research. After special design, the system can still realize high-efficiency operation under the condition of unstable exhaust temperature and gas quality; Important parts can withstand the common impurities in landfill gas and ensure the long-term stable operation of the system.

Waste gas treatment of natural gas power generation


Green Valley environmental protection has developed a set of "grvnes" SCR denitration system for the treatment of nitrogen oxides in gas power generation after years of painstaking research. After special design, the system can still realize high-efficiency operation under the condition of unstable exhaust temperature and gas quality; Important parts can withstand the common impurities in landfill gas and ensure the long-term stable operation of the system.

Treatment of waste gas from anaerobic biogas power generation


Green Valley environmental protection has developed a set of "grvnes" SCR denitration system for nitrogen oxide treatment in anaerobic biogas power generation after years of painstaking research. After special design, the system can still realize high-efficiency operation under the condition of unstable exhaust temperature and gas quality; Important parts can withstand the common impurities in landfill gas and ensure the long-term stable operation of the system.

Waste gas treatment of gas power generation


Green Valley environmental protection has developed a set of "grvnes" SCR denitration system for nitrogen oxide treatment in landfill gas power generation after years of painstaking research. After special design, the system can still realize high-efficiency operation under the condition of unstable exhaust temperature and gas quality; Important parts can withstand the common impurities in landfill gas and ensure the long-term stable operation of the system.

Treatment of waste gas from biomass biogas power generation


Green Valley environmental protection has developed a set of "grvnes" SCR denitration system for the treatment of nitrogen oxides in biomass biogas power generation after years of painstaking research. After special design, the system can still realize high-efficiency operation under the condition of unstable exhaust temperature and gas quality; Important parts can withstand the common impurities in landfill gas and ensure the long-term stable operation of the system.

Advisory Message

If you need to know more information and products about Green Valley Environmental Protection, you can contact us by leaving a message or by phone, and we will provide you with professional services and products. Welcome to call the service hotline:+86-769-89957788